Sub-Zero® Refrigeration
Error / Fault codes
400 SERIES WINE STORAGE
Possible Error Indicators
NOTE: Temperatures shown are for reference only, actual temperatures
may vary.
55 SERVICE (Flashing) EE
Upper compartment thermistor fault
BELL ON (Flashing)
55 SERVICE (Flashing) EE
Upper compartment thermistor fault with temperature alarm
EE SERVICE (Flashing) 55
Lower compartment thermistor fault
BELL ON (Flashing)
EE SERVICE (Flashing) 55
Lower compartment thermistor fault with temperature alarm
55 SERVICE (Flashing) 55
Either evaporator thermistor fault
BELL ON (Flashing)
55 SERVICE (Flashing) 55
Either evaporator thermistor fault with temperature alarm
NOTE: Cooling functions are disabled when error indicators appear.
400 SERIES, MODEL 427R REFRIGERATOR
Possible Error Indicators
NOTE: Temperature shown is for reference only, actual temperature
may vary.
TOP DRAWER (Flashing)
EE LOWER DRAWER (Flashing)
Refrigerator compartment thermistor fault
TOP DRAWER (Flashing)
40 LOWER DRAWER (Flashing)
Refrigerator evaporator thermistor fault.
E0
700BR & 700BF Communication Error between
Control Board & Control Panel
E3
700BR & 700BF Communication Error between
Control Board & Control Panel
400-2 SERIES WINE STORAGE
Possible Error Indicators
NOTE: Temperatures shown are for reference only, actual temperatures
may vary.
55 SERVICE (Flashing) EE
Upper compartment thermistor fault
BELL ON (Flashing)
55 SERVICE (Flashing) EE
Upper compartment thermistor fault with temperature alarm
EE SERVICE (Flashing) 55
Lower compartment thermistor fault
BELL ON (Flashing)
EE SERVICE (Flashing) 55
Lower compartment thermistor fault with temperature alarm
55 SERVICE (Flashing) 55
Either evaporator thermistor fault
BELL ON (Flashing)
55 SERVICE (Flashing) 55
Either evaporator thermistor fault with temperature alarm
NOTE: Cooling functions are disabled when error indicators appear.
400-2 SERIES WINE STORAGE
| CODE | INDICATION |
| 05 | Upper Cabinet Thermistor read open / short for 10+ seconds, or repeatedly erratic temp’s. |
| 06 | Upper Evap. Thermistor read open / short for 10+ seconds, or repeatedly erratic temp’s. |
| 07 | Lower Cabinet Thermistor read open / short for 10+ seconds, or repeatedly erratic temp’s. |
| 08 | Lower Evap. Thermistor read open / short for 10+ seconds, or repeatedly erratic temp’s. |
| 10 | Upper Cabinet Warm Temperature alarm |
| 11 | Upper Cabinet Cold Temperature alarm |
| 12 | Lower Cabinet Warm Temperature alarm |
| 13 | Lower Cabinet Cold Temperature alarm |
| 15 | Sealed System Fault (evap temp. cannot drop 5° in 5 minutes, 3 consecutive valve activations) |
400-2 SERIES - 427R-2 REFRIGERATOR
| CODE | INDICATION |
| 05 | Upper Cabinet Thermistor read open / short for 10+ seconds, or repeatedly erratic temp’s. |
| 50 | Excessive Refrigerator compressor run |
600 SERIES (Prior To Serial #1810000)
Possible Error Indicators
NOTE: Temperatures shown are for reference only, actual temperatures
may vary.
EE SERVICE (Flashing) 38
Freezer compartment thermistor Fault
00 SERVICE (Flashing) EE
Refrigerator compartment thermistor fault
00 SERVICE (Flashing) 38
Refrigerator evaporator thermistor fault
SERVICE (Flashing)
00 ICE (Flashing) 38
Water valve energized longer than 15 seconds. Icemaker
system disabled.
NOTE: A 45 minute dwell follows each IM cycles (no power
to Icemaker). To bypass 45 minute dwell, Switch unit OFF
then back ON.
SERVICE (Flashing)
12 VACUUM (Flashing) 45
CONDENSER
Several excessive compressor run periods
600 SERIES (Starting With Serial #1810000)
Possible Error Indicators
NOTE: Temperatures shown are for reference only, actual temperatures
may vary.
EE SERVICE (Flashing) 38
Freezer compartment thermistor fault
00 SERVICE (Flashing) EE
Refrigerator compartment thermistor fault
00 SERVICE (Flashing) 38
Several excessive compressor run periods OR
Refrigerator evaporator thermistor fault
SERVICE (Flashing)
00 ICE (Flashing) 38
Water valve energized longer than 15 seconds. Icemaker
system disabled.
NOTE: A 45 minute dwell follows each IM cycles (no power
to Icemaker). To bypass 45 minute dwell, Switch unit OFF
then back ON.
600 SERIES (Starting With Serial #1810000)
| CODE | INDICATION |
| 05 | Refrig. Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
| 06 | Refrig. Evaporator Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
| 07 | Freezer Cabinet Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
| 08 | Freezer Evaporator Thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
| 20 | Defrost Underheat with No Voltage Feedback Through Gray/White Wire at Defrost Start |
| 21 | Defrost Overheat |
| 22 | No Voltage Feedback Through Gray/White Wire at Defrost Start |
| 23 | Defrost Overheat with No Voltage Feedback through Gray/White Wire at Defrost Start |
| 24 | Defrost Underheat |
600-2 SERIES
Possible Error Indicators
NOTE: Temperatures shown are for reference only, actual temperatures
may vary.
EE SERVICE (Flashing) 38
Freezer compartment thermistor fault
00 SERVICE (Flashing) EE
Refrigerator compartment thermistor fault
00 SERVICE (Flashing) 38
Several excessive compressor run periods OR
Refrigerator evaporator thermistor fault
SERVICE (Flashing)
00 ICE (Flashing) 38
Water valve energized longer than 15 seconds, five consecutive
times. Icemaker system disabled 24 hours each time.
NOTE: A 45 minute dwell follows each IM cycles (no power
to Icemaker). To bypass 45 minute dwell, Switch ice maker
system OFF then back ON.
00 SERVICE (Steady, not Flashing)38
Error Codes logged and observed but not cleared.
600-2 SERIES
| CODE | INDICATION |
| 05 | Ref. cabinet therm. read open, short or erratic temp for 10+ sec’s |
| 06 | Ref. evap. therm. read open, short or erratic temp for 10+ sec’s |
| 07 | Fre. cabinet therm. read open, short or erratic temp for 10+ sec’s |
| 08 | Fre. evap. therm. read open, short or erratic temp for 10+ sec’s |
| 20 | Defrost underheat & no feedback thru Gr/Wh wire at defrst start |
| 21 | Defrost overheat |
| 22 | No feedback thru Gr/Wh wire at defrost start |
| 23 | Defrost overheat & no feedback thru Gr/Wh wire at defrost start |
| 24 | Defrost underheat |
| 30 | Excess IM Water Valve Solenoid Activation (> 15 Seconds) |
| 40 | Excessive Freezer Comp Run |
| 50 | Excessive Refrigerator Comp Run |
700 SERIES
Possible Error Indicators
- -
“- -” = Control is shut off. Press COLDER key to start unit.
- 20
“- 20 ” = Zone/Compartment thermistor fault. Repair wiring
or replace thermistor.
55
“55” = Zone/Compartment thermistor shorted. Repair wiring
or replace thermistor.
Su
“Su” = Blue wire of display cable unhooked or faulty. Repair
wiring.
- 88
“- 88 ” = Red Wire of display cable unhooked or faulty, top
lights are off and keys are inoperative. Repair wiring.
700-2 SERIES (Tall Units)
Possible Error Indicators
NOTE: Temperatures shown are for reference only, actual temperatures
may vary.
EE SERVICE (Flashing) 38
Freezer compartment thermistor Fault
00 SERVICE (Flashing) EE
Refrigerator compartment thermistor fault
00 SERVICE (Flashing) 38
Several excessive compressor run periods OR
Refrigerator evaporator thermistor fault
SERVICE (Flashing)
00 ICE (Flashing) 38
Water valve energized longer than 15 seconds. Icemaker
system disabled.
NOTE: A 45 minute dwell follows each IM cycles (no power
to Icemaker). To bypass 45 minute dwell, Switch unit OFF
then back ON.
700-2 SERIES (Tall Units)Starting W/ Serial #1759163
| CODE | INDICATION |
| 05 | Ref. cabinet therm. read open, short or erratic temp for 10+ sec’s |
| 06 | Ref. evap. therm. read open, short or erratic temp for 10+ sec’s |
| 07 | Fre. cabinet therm. read open, short or erratic temp for 10+ sec’s |
| 08 | Fre. evap. therm. read open, short or erratic temp for 10+ sec’s |
| 20 | Defrost underheat & no feedback thru Gr/Wh wire at defrst start |
| 21 | Defrost overheat |
| 22 | No feedback thru Gr/Wh wire at defrost start |
| 23 | Defrost overheat & no feedback thru Gr/Wh wire at defrost start |
| 24 | Defrost underheat |
| 80 | High VS compressor differential pressures or low voltage supplied to VS compressor |
| 81 | High Amperage Draw at VS compressor |
| 82 | VS comp. couldn’t maintain min. speed at highest current draw |
| 83 | Locked VS compressor Rotor |
| 84 | Short circuit at VS compressor controller output circuit |
| 85 | VS compressor inverter overheated & shut down VS compressor |
| 86 | Serial communication failure between VS compressor controller and electronic control board |
| 87 | Speed information from electronic control board is out of spec. |
| 88 | Electronic control board not receiving status data in response to speed commands |
700-3 SERIES - TALL UNITS
| CODE | INDICATION |
| 05 | Ref. cabinet therm. read open, short or erratic temp for 10+ sec’s |
| 06 | Ref. evap. therm. read open, short or erratic temp for 10+ sec’s |
| 07 | Fre. cabinet therm. read open, short or erratic temp for 10+ sec’s |
| 08 | Fre. evap. therm. read open, short or erratic temp for 10+ sec’s |
| 20 | Defrost underheat & no feedback thru Gr/Wh wire at defrst start |
| 21 | Defrost overheat |
| 22 | No feedback thru Gr/Wh wire at defrost start |
| 23 | Defrost overheat & no feedback thru Gr/Wh wire at defrost start |
| 24 | Defrost underheat |
| 30 | Excess IM Water Valve Solenoid Activation (> 15 Seconds) |
| 40 | Excessive Freezer Comp Run |
| 50 | Excessive Refrigerator Comp Run |
700-3 SERIES - BASE UNITS
| CODE | INDICATION |
| 05 | Ref. cabinet therm. read open, short or erratic temp for 10+ sec’s |
| 06 | Ref. evap. therm. read open, short or erratic temp for 10+ sec’s |
| 07 | Fre. cabinet therm. read open, short or erratic temp for 10+ sec’s |
| 08 | Fre. evap. therm. read open, short or erratic temp for 10+ sec’s |
| 20 | Defrost underheat & no feedback thru Gr/Wh wire at defrst start |
| 21 | Defrost overheat |
| 22 | No feedback thru Gr/Wh wire at defrost start |
| 23 | Defrost overheat & no feedback thru Gr/Wh wire at defrost start |
| 24 | Defrost underheat |
| 30 | NA |
| 40 | Excessive Freezer Comp Run |
| 50 | Excessive Refrigerator Comp Run |
SubZero Refrigerators Fault Codes
No 'surprises'
Featured Brands
Sub-Zero: Fridges,free-standing, built-in.
cooking, ventilation